10 - Water Heater Specifications
10-A
MULTIPLE UNIT HEATERS
1. No heater
with less than a thirty-gallon tank shall be served under storage
water heater rates.
2. All heaters
shall be insulated storage tank heaters equipped with two heating
units each controlled by a separate thermostat and carry the
seal of approval of the Underwriter's Laboratories, Incorporated.
3. The upper
unit and thermostat shall be located approximately one-quarter
of the tank capacity below the top of the tank.
4. The bottom
or storage unit and thermostat shall be located near the bottom
of the tank.
5. The water
heater must have provisions for the installation of a temperature
pressure relief valve at the top of the tank.
6. The quick
recovery type water heater with two 4500 watt interlocked elements
will be accepted on the water heating rate.
10-B WATER
HEATER OPERATION. At the Company's option, the operation of
the water heater may be controlled by a time switch or other
device which will disconnect the bottom or storage unit of the
multiple unit heater during such periods of each day that the
Company may designate, provided, however, that the total of
such periods shall in no case exceed seven hours per day.